Technische Universität Ilmenau

Active Filters and Power Flow Control - Modultafeln of TU Ilmenau

The module lists provide information on the degree programmes offered by the TU Ilmenau.

Please refer to the respective study and examination rules and regulations for the legally binding curricula (Annex Curriculum).

You can find all details on planned lectures and classes in the electronic university catalogue.

Information and guidance on the maintenance of module descriptions by the module officers are provided at Module maintenance.

Please send information on missing or incorrect module descriptions directly to modulkatalog@tu-ilmenau.de.

module properties module number 5885 - common information
module number5885
departmentDepartment of Electrical Engineering and Information Technology
ID of group2161 (Power Electronics and Control)
module leaderProf. Dr. Albrecht Gensior
languageDeutsch, auf Nachfrage Englisch
term Wintersemester
previous knowledge and experience

· Grundlagen der Leistungselektronik
· Grundkenntnisse zum Simulationssystem Matlab/Simulink

· Basics of Power Electronics
· Basic knowledge about Simulation using Matlab/Simulink

learning outcomeDie Studierenden sind in der Lage, elektrische Netze und Verbraucher zu analysieren und die richtigen Maßnahmen zur Verbesserung oder Absicherung der Energiequalität des Netzknotenpunktes zu ermitteln und die geeigneten Schaltungen zur Verbesserung der Eigenschaften auszuwählen. Sie sind fähig, für vorhandene elektrische Netze aktive Filter zu projektieren, auszulegen und in Betrieb zu setzen. Sie sind in der Lage, die Möglichkeiten zur Verbesserung der Energiequalität einzuschätzen und die geeigneten Filtertopologien auswählen.Sie können bei Notwendigkeit sehr große Systeme simulieren, diese analysieren, um optimale Strukturen und Parameter zu finden.
The students are able to analyse the electrical grid and loads, to develop a method and to identify the right topology to improve the power quality. They should be able to develop and implement active filter topologies. They will be able to identify the possibility of improving the power quality and to design the corresponding filter topology. If necessary, they should be able to simulate the complex systems, to find the optimal system configuration.
content

· Netzrückwirkung von Gleichrichterschaltungen
· Filterkreise am Netzanschlusspunkt
· Power Factor Correction (PFC)- Methoden
  - am einphasigen Netz
  - am Drehstromnetz
· aktive Filter zur Oberschwingungskompensation
  Parallelfilter (shunt active Filter)
  Reihenfilter (series active Filter)
  Hybridfilter (hybrid active Filter)
· Energetische Betrachtungen des Zusammenwirkens des leistungselektronischen Stellgliedes mit dem elektrischen Netz
· Anforderungen an die Steuerung und Regelung
· einsetzbare Komponenten (technische Umsetzung)
· Netzausfallerkennung
· Simulation des Gesamtsystems
· Probleme der elektromagnetischen Verträglichkeit
· Power quality
· Power factor correction methods
· Passive filters for reactive power and harmonic compensation
· Active power filters for reactive power and harmonic compensation
   - shunt active filters
   - series active filters
   - hybrid active filters
· Interconnection between mains and converters
· Demands on the control circuits
· Technical realisation of active power filters
· Mains failure detection
· Simulations of active filters
· Problems on EMI/EMC

media of instruction and technical requirements for education and examination in case of online participation

Arbeitsblätter, Rechnerübung, Exkursion, Projektarbeit, Simulationen work sheets, PC training, excursion, project work, simulation

literature / references

· Tagungsbände der bekannten internationalen Leistungselektroniktagungen des IEEE
· IEEE-Zeitschriften "Transactions on Power Electronics", "Transactions on Industrial Applications"
· Proceedings of the well known IEEE conferences for power electronics
· IEEE-Journal "Transactions on Power Electronics", "Transactions on Industrial Applications"

evaluation of teaching

Pflichtevaluation:

Freiwillige Evaluation:

Hospitation:

Details reference subject
module nameActive Filters and Power Flow Control
examination number2100304
credit points4
SWS3
on-campus program (h)33.75
self-study (h)86.25
obligationobligatory module
examoral examination performance, 45 minutes
details of the certificate
alternative examination performance due to COVID-19 regulations incl. technical requirements
signup details for alternative examinations
maximum number of participants
Details in degree program Master Electrical Power and Control Engineering 2008
ATTENTION: not offered anymore
module nameActive Filters and Power Flow Control
examination number2100304
credit points4
on-campus program (h)34
self-study (h)86
obligationobligatory module
examoral examination performance, 45 minutes
details of the certificate
alternative examination performance due to COVID-19 regulations incl. technical requirements
signup details for alternative examinations
maximum number of participants