The years 2002-2005 are not digitally mapped.

Order: descending chronological (most recent first)

 
Results: 294
Created on: Thu, 09 May 2024 23:18:01 +0200 in 0.1085 sec


Fröber, Ulrike; Stubenrauch, Mike; Weiß, Thomas; Berg, A.; Voges, Danja; Schade, R.; Hildebrand, Gerhard; Schnabelrauch, M.; Liefeith, Klaus; Hoffmann, Martin; Witte, Hartmut
Microsystems for the characterization of 3D-ECM analogous bio-interfaces. - In: Biomaterials, cellular and tissue engineering, artificial organs, (2009), S. 94-97

Sang, Shengbo; Fröber, Ulrike; Witte, Hartmut
Concept of a microfluidics and tunneling effect-based BioMEMS to detect cells. - In: Micro- and nanosystems in medicine, active implants, biosensors, (2009), S. 144-147

Nowack, Tobias; Lutherdt, Stefan; Kurtz, Peter; Witte, Hartmut
Analyse von Bewegungsmustern an 3D-Eingabegeräten mittels Bewegungsanalyse. - In: Der Mensch im Mittelpunkt technischer Systeme, (2009), S. 116-122

An der Technischen Universität Ilmenau (Fachgebiete Arbeitswissenschaft und Biomechatronik) wurde ein Bewegungsanalysesystem auf seine Eignung zur Untersuchung von 3DEingabegeräten überprüft. Daraus resultierende erste Ergebnisse werden mit dieser Arbeit vorgestellt. Die grundsätzliche Eignung des Bewegungsanalysesystems wurde ebenso festgestellt wie die der verwendeten Testumgebung mit der zugehörigen Software. Dazu wurden die Bewegungsdaten von 35 an den Probanden befestigten Markern und die Logdaten der benutzten 3D-Eingabegeräte (Gamepad, Joystick und Haptor) während der Abarbeitung einer standardisierten Testaufgabe erfasst und ausgewertet. - Durch die Analyse der Logdaten konnte gezeigt werden, dass sich die verwendeten Eingabegeräte bezüglich der Ausführungszeiten einzelner Teilaufgaben unterscheiden. Neben den unterschiedlichen Zeiten zur Abarbeitung der einzelnen Teilaufgaben zeigten die Logfiles auch Unterschiede in den Abweichungen der durchgeführten Bewegungen von der als Ideallinie definierten kürzesten Verbindung zwischen den Start- und Zielkoordinaten der jeweiligen Teilaufgaben. Durch die Bewegungsanalyse konnten bei einigen Probanden spezifische Bewegungsmuster in Abhängigkeit vom genutzten Gerätetyp wiederholt auch nach physischer Belastung nachgewiesen werden. Jedoch konnten solche Muster nicht als gerätespezifisch gleichbleibend über die gesamte Gruppe hinweg gefunden werden.



Lutherdt, Stefan; Stiller, Carsten; Lienert, Katrin; Spittel, Sabine; Roß, Fred; Ament, Christoph; Witte, Hartmut
Design of an assistance system for elderly based on analyses of needs and acceptance. - In: Universal access in human-computer interaction, (2009), S. 96-105

http://dx.doi.org/10.1007/978-3-642-02707-9_11
Mämpel, Jörg; Gerlach, Kurt; Schilling, Cornelius; Witte, Hartmut
A modular robot climbing on pipe-like structures. - In: 4th International Conference on Autonomous Robots and Agents, 2009, ISBN 978-1-4244-2712-3, (2009), S. 87-91

http://dx.doi.org/10.1109/ICARA.2000.4803967
Nowack, Tobias; Lutherdt, Stefan; Möller, Manuel; Kurtz, Peter; Witte, Hartmut
Improvement of the design quality of 3D-input devices using motion analyses and biomechanical comparisons. - In: Ergonomics and health aspects of work with computers, (2009), S. 276-285

Due to the lack of investigations and standards describing the design of real 3D input devices a real 3D input device was develop. To compare several devices a test task was created and performed with combination of a motion capturing system. During the experiment 19 attendees with different levels of experience performed the test with this setup. Several intra-individual motion patterns and using strategies belonging to different input devices could be observed.



http://dx.doi.org/10.1007/978-3-642-02731-4_33
Stubenrauch, Mike; Fröber, Ulrike; Fischer, Michael; Kremin, Christoph; Witte, Hartmut; Hoffmann, Martin
Klebe- und klemmfreies Anschlusskonzept für mikrofluidische Systeme mittels nanostrukturierter Oberflächen. - In: Mikro-Nano-Integration, (2009), insges. 2 S.

Stubenrauch, Mike; Fröber, Ulrike; Voges, Danja; Schilling, Cornelius; Hoffmann, Martin; Witte, Hartmut
A modular BioMEMS platform for new procedures and experiments in tissue engineering. - In: Journal of micromechanics and microengineering, ISSN 1361-6439, Bd. 19 (2009), 7, 074013, insges. 6 S.

https://doi.org/10.1088/0960-1317/19/7/074013
Witte, Hartmut
Zur technischen Biologie des Kletterns. - In: Bionik: Patente aus der Natur, (2009), S. 196-206

Müller, Alexander; Schmidt, Tobias; Elste, Thomas; Sachs, Martin; Töpfer, Hannes; Witte, Hartmut
Schutz der Beschäftigten vor Gefährdungen durch Lärm im Sinne der Lärm-und Vibrations-Arbeitsschutzverordnung mit Hilfe personalisierter miniaturisierter Lärm-Dosimeter (PMD). - In: Lärmbekämpfung, ISSN 1863-4672, Bd. 4 (2009), 3, S. 116-121