Augustin, Silke; Fröhlich, Thomas; Krapf, Gunter; Bergmann, Jean Pierre; Grätzel, Michael; Gerken, Jan Ansgar; Schmidt, Kiril
Challenges of temperature measurement during the friction stir welding process. - In: Measuring Equipment and Metrology, ISSN 2617-846X, Bd. 81 (2020), 1, insges. 8 S.

The exact determination of the process zone temperature can be considered as an increasingly important role in the control and monitoring of the friction stir welding process (FSW). At present, temperature measurement is carried out with the aid of a temperature sensor integrated into the tool (usually thermocouples). Since these cannot be attached directly to the joining area, heat dissipation within the tool and to the environment cause measurement deviations as well as a time delay in the temperature measurement. The article describes a process and the challenges that arise in this process, how a direct temperature measurement during the process can be achieved by exploiting the thermoelectric effect between tool and workpiece, without changing the tool by introducing additional temperature sensors.



https://doi.org/10.23939/istcmtm2020.01.034
Weidenfeller, Bernd; Rode, Hauke; Mohr-Weidenfeller, Laura; Weidenfeller, Katrin
Crystallinity, thermal diffusivity, and electrical conductivity of carbon black filled polyamide 46. - In: Journal of applied polymer science, ISSN 1097-4628, Bd. 137 (2020), 29, 48882, S. 1-10

https://doi.org/10.1002/app.48882
Shih, Yi-Chieh; Tung, Pi-Cheng; Wang, Yung-Cheng; Shyu, Lih-Horng; Manske, Eberhard
Linear displacement calibration system integrated with a novel auto-alignment module for optical axes. - In: Sensors, ISSN 1424-8220, Bd. 20 (2020), 9, 2462, insges. 13 S.

https://doi.org/10.3390/s20092462
Germanow, Philipp; Mehring, Patrick; Neumann, Herbert; Augustin, Silke; Fröhlich, Thomas; Krapf, Gunter
Comparison of different methods for experimental determining the inhomogeneity of thermocouples :
Vergleich verschiedener Methoden zur experimentellen Bestimmung der Inhomogenität von Thermoelementen. - In: Technisches Messen, ISSN 2196-7113, Bd. 87 (2020), 3, S. 146-152

https://doi.org/10.1515/teme-2019-0138
Stauffenberg, Jaqueline; Durstewitz, Steve; Hofmann, Martin; Ivanov, Tzvetan; Holz, Mathias; Ehrhardt, Waleed; Riegel, Wolf-Ulrich; Zöllner, Jens-Peter; Manske, Eberhard; Rangelow, Ivo W.
Determination of the mixing ratio of a flowing gas mixture with self-actuated microcantilevers. - In: Journal of sensors and sensor systems, ISSN 2194-878X, Bd. 9 (2020), 1, S. 71-78

https://doi.org/10.5194/jsss-9-71-2020
Hofmann, Martin; Mohr-Weidenfeller, Laura; Supreeti, Shraddha; Mechold, Stephan; Holz, Mathias; Reuter, Christoph; Sinzinger, Stefan; Manske, Eberhard; Rangelow, Ivo W.
Mix-and-match lithography and cryogenic etching for NIL template fabrication. - In: Microelectronic engineering, Bd. 224 (2020), 111234

https://doi.org/10.1016/j.mee.2020.111234
Pabst, Markus; Darnieder, Maximilian; Theska, René; Fröhlich, Thomas
Measuring and adjusting the stiffness and tilt sensitivity of a novel 2D monolithic high precision electromagnetic force compensated weighing cell. - Boulder, Colo. : NCSL International. - 1 Online-Ressource (1 Seite)Publikation entstand im Rahmen der Veranstaltung: Metrology in motion : NCSLI workshop & symposium, August 24-29, 2019

Further improvements in high precision mass comparison are a recent issue in the dissemination chain of the mass standard. One of the most precise methods of mass comparison is achieved by the use of high precision electromagnetic force compensated (EMFC) weighing cells as part of mass comparators. The mechanics of EMFC weighing cells are based on compliant mechanisms with concentrated compliances in form of flexure hinges. Total mechanical stiffness and tilt sensitivity are limiting factors with regard to the resolution of EMFC weighing cells. In order to optimize their performance, the stiffness and the tilt sensitivity of the systems need to be minimized. Due to manufacturing restrictions and robustness requirements, a further reduction of the thickness of the pivots is not desirable. In this paper, an alternative to reduce stiffness and tilt sensitivity by adding trim weights in combination with an astasizing adjustment is presented. Based on the results of the investigations, a new planar monolithic mechanism for an EMFC weighing cell is designed, providing the possibility to adjust trim masses. The new mechanism is set up and adjusted according to the developed mechanical model. A parameter combination for a total stiffness slightly above zero and a tilt sensitivity close to zero is found. For the evaluation of the adjustment success and the vacuum compatibility, the system is tested under high vacuum conditions.



https://doi.org/10.51843/wsproceedings.2019.13
Krey, Maximilian; Töpfer, Hannes; Paris, Roman; Fröhlich, Thomas
Design of a test station for magnetoelectric sensor development. - In: 2019 19th International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering (ISEF 2019) - book of abstracts, (2019), insges. 2 S.

https://doi.org/10.1109/ISEF45929.2019.9097048
Brethauer, Andreas;
Entwicklung einer Methode zur Temperaturbestimmung von Fluiden mithilfe von Berührungsthermometern bei niedrigen Eintauchtiefen. - Ilmenau : Universitätsverlag Ilmenau, 2019. - 1 Online-Ressource (XVI, 229 Seiten)
Technische Universität Ilmenau, Dissertation 2019

Die exakte Bestimmung der Temperatur gewinnt u. a. in der Wärmeverbrauchsmessung eine immer höhere Bedeutung. Hier wird mithilfe der Temperaturdifferenz an einem Vor- und Rücklauf in Kombination mit der Durchflussmenge die entnommene Wärme bestimmt. Messabweichungen haben hier eine direkte Auswirkung auf die Kostenabrechnung. Konstruktionsbedingt ist bei den gängigen Wärmemengenzählern an der Thermometer-Einbaustelle des Rücklaufs nur wenig Platz. Hier wird häufig tangential in das Medium eingetaucht, was eine nicht vernachlässigbare Messabweichung verursacht. In der Arbeit wird die Messabweichung durch Wärmeableitung und das Ansprechverhalten von Widerstandsthermometern bei geringen Eintauchtiefen in ein zu messendes Medium näher untersucht. Dabei wird die Bedeutung einer thermischen Ankopplung des Sensors an das Medium, sowie die Entkopplung von der anders temperierten Umgebung deutlich. Einen Einfluss hat auch das verwendete Medium. In der Wärme-/Kälteübertragung werden häufig Wasser-Glykol-Gemische verwendet. Deren Verwendung hat gerade bei niedrigen Strömungsgeschwindigkeiten einen hohen Einfluss auf die thermische Messabweichung und das Ansprechverhalten eines Widerstandsthermometers. Zudem wurde auch die Möglichkeit zur Nutzung des Loop Current Step Response Tests in der Wärmeverbrauchsmessung validiert. Dies erlaubt das Messen von Ansprechzeiten unter Einbaubedingungen. Ziel der Arbeit ist die Nutzbarmachung erzielter Erkenntnisse. So wurde eine Prüfeinrichtung zur Untersuchung von Widerstandsthermometern unter Einbaubedingungen entwickelt und validiert. Diese, als Strömungskanal konzipierte Prüfeinrichtung, erlaubt die Untersuchung des statischen und dynamischen Verhaltens von Thermometern, sowie den direkten Vergleich unterschiedlicher Einbaustellen. Die Messstrecken sind über ein Kleinflansch-Verbindungssystem austauschbar. Die Durchführung und Auswertung der unterschiedlichen Messprogramme läuft automatisch über eine eigens entwickelte Software ab. Eine weitere Neuentwicklung ist ein für niedrige Eintauchtiefen optimiertes Widerstandsthermometer. Hier wurden wärmeleitfähige und thermisch isolierende Kunststoffe kombiniert. So wurde eine gute Ankopplung des Temperatursensors an das zu messende Medium, sowie eine Entkopplung von der anders temperierten Umgebung realisiert.



https://nbn-resolving.org/urn:nbn:de:gbv:ilm1-2019000157
Vasilyan, Suren; Rogge, Norbert; Fröhlich, Thomas
Metrology in direct photon momentum measurement. - In: Messunsicherheit - Prüfprozesse 2019, (2019), S. 193-205