Gesamtliste der Publikationen

Anzahl der Treffer: 992
Erstellt: Thu, 16 May 2024 23:07:30 +0200 in 0.0745 sec


Stauffenberg, Jaqueline; Ortlepp, Ingo; Reuter, Christoph; Holz, Mathias; Dontsov, Denis; Schäffel, Christoph; Strehle, Steffen; Zöllner, Jens-Peter; Rangelow, Ivo W.; Manske, Eberhard
Investigations on long-range AFM scans using a nanofabrication machine (NFM-100). - In: Proceedings, ISSN 2504-3900, Volume 56 (2020), issue 1, 34, Seite 1-3

The focus of this work lies on investigations on a new Nano Fabrication Machine (NFM-100) with a mounted atomic force microscope (AFM). This installed tip-based measuring system uses self-sensing and self-actuated microcantilevers, which can be used especially for field-emission scanning probe lithography (FESPL). The NFM-100 has a positioning range of Ø 100 mm, which offers, in combination with the tip-based measuring system, the possibility to analyse structures over long ranges. Using different gratings, the accuracy and the reproducibility of the NFM-100 and the AFM-system will be shown.



https://doi.org/10.3390/proceedings2020056034
Dannberg, Oliver;
Entwicklung eines Prüfstandes zur rückführbaren Kalibrierung von Cantilevern. - Ilmenau : Universitätsbibliothek, 2020. - 1 Online-Ressource (ii, 109 Seiten)
Technische Universität Ilmenau, Dissertation 2020

Zur rückführbaren Messung von Kräften im Bereich von Nanonewton werden typischerweise AFM Cantilever verwendet, deren Durchbiegung in guter Näherung proportional zur eingeleiteten Kraft ist. Die Proportionalitätskonstante zwischen den Größen wird durch die Steifigkeit des Cantilevers beschrieben. In dieser Arbeit wird die Konzeption, Entwickelung und Analyse eines Prüfstandes zur Vermessung der Steifigkeiten von Cantilevern beschrieben. Dazu wird der Cantilever an einem Halter befestigt und durch einen Piezoantrieb auf die Oberfläche eines Diamanttasters gedrückt. Die Auslenkung des Cantilevers wird durch ein Differenzinterferometer und die dafür notwendige Kraft mit einer neu entwickelten EMK-Wägezelle gemessen. Der Mechanismus der monolithischen Wägezelle ist durch die Verwendung eines einzelnen Drehgelenks sehr weich und ermöglicht dadurch eine hohe Kraftauflösung. Die Position des Wägebalkens wird durch ein weiteres Differenzinterferometer gemessen und mit einem PID-Regler zu Null geregelt. In zwei unabhängigen Verfahren wurde in guter Übereinstimmung die effektive Kraftkonstante der Wägezelle auf Bl = 25,9 mN/A bestimmt. Der Prüfstand wurde hinsichtlich seiner Eigenschaften untersucht und die Einflussgrößen auf die Messunsicherheit der Cantileversteifigkeit identifiziert. Die Kalibrierung eines weichen Cantilever ergab eine relative Messunsicherheit von 1,5 % (k = 2) bei einer Kalibrierkraft < 100 nN. Bei der anschließenden Untersuchung der Spitze waren keine Schäden festzustellen. Die Messung eines zweiten Cantilevers ergab eine gute Wiederholbarkeit der Kalibrierergebnisse. Außerdem wurden die durch diesen Prüfstand erzielten Ergebnisse mit den Resultaten eines an deren Prüfstandes verglichen und zeigten gute Übereinstimmung.



https://nbn-resolving.org/urn:nbn:de:gbv:ilm1-2020000578
Ortlepp, Ingo; Manske, Eberhard; Zöllner, Jens-Peter; Rangelow, Ivo W.
Phase-modulated standing wave interferometer. - In: Proceedings, ISSN 2504-3900, Volume 56 (2020), issue 1, 12, Seite 1-3

Standing wave interferometers (SWIs) show enormous potential for miniaturization because of their simple linear optical set-up, consisting only of a laser source, a measuring mirror and two standing wave sensors for obtaining quadrature signals. To reduce optical influences on the standing wave and avoid the need for an exact and long-term stable sensor-to-sensor distance, a single-sensor set-up was developed with a phase modulation by forced oscillation of the measuring mirror. When the correct modulation stroke is applied, the harmonics in the sensor signal can be used for obtaining quadrature signals for phase demodulation and direction discrimination.



https://doi.org/10.3390/proceedings2020056012
Röse, Anni; Liu, Yang; Köchert, Paul; Prellinger, Günther; Manske, Eberhard; Pollinger, Florian
Modulation-based long-range interferometry as basis for an optical two-color temperature sensor. - In: Proceedings of the 20th International Conference of the European Society for Precision Engineering and Nanotechnology, (2020), S. 299-300

Darnieder, Maximilian; Pabst, Markus; Fröhlich, Thomas; Theska, René
Corner loading and its influence on the tilt sensitivity of precision weighing cells. - In: Proceedings of the 20th International Conference of the European Society for Precision Engineering and Nanotechnology, (2020), S. 95-98

Dannberg, Oliver; Kühnel, Michael; Fröhlich, Thomas
Development of a cantilever calibration device :
Entwicklung einer Cantileverkalibriereinrichtung. - In: Technisches Messen, ISSN 2196-7113, Bd. 87 (2020), 10, S. 622-629

Das Messen kleiner Kräfte ist in vielen wissenschaftlichen Bereichen, wie beispielsweise der Physik oder Biologie, erforderlich. Bei Kräften im Bereich von Nanonewton werden typischerweise AFM-Cantilever als Kraftsensoren genutzt. Die Steifigkeit des Cantilevers muss bekannt sein um von der Durchbiegung auf die Kraft zu schließen. Aufgrund von Fertigungsabweichungen kommt es zu einer großen Streuung der Cantileversteifigkeit. Für eine präzise Kraftmessung muss daher jeder einzelne Cantilever kalibriert werden. Das derzeit genauste Kalibrierverfahren basiert darauf die Kraft-Weg-Kennlinie des Cantilevers statisch zu messen und ihren Anstieg zu bestimmen. In diesem Artikel wird ein neuartiger Prüfstand beschrieben welcher nach diesem Prinzip arbeitet. Ein Interferometer misst die Position und eine neuartige, eingelenkige Wägezelle die Kraft des Cantilevers. Die Wägezelle wurde in zwei unabhängigen Experimenten mit übereinstimmendem Ergebnis kalibriert. Abschließend werden die Messergebnisse einer Cantileverkalibrierung präsentiert.



https://doi.org/10.1515/teme-2020-0064
Lin, Shan; Rothleitner, Christian; Rogge, Norbert; Vasilyan, Suren; Fröhlich, Thomas; Härtig, Frank; Knopf, Dorothea
Towards a table-top Kibble balance for E1 mass standards in a range from 1 mg to 1 kg - Planck-Balance 1 (PB1). - In: 2020 Conference on Precision Electromagnetic Measurements (CPEM), (2020), insges. 2 S.

https://doi.org/10.1109/CPEM49742.2020.9191883
Kacker, Raghu N.; Kessel, Rüdiger; Sommer, Klaus-Dieter
Operational measurement uncertainty and Bayesian probability distribution. - In: SMSI 2020, (2020), S. 275-276
Richtiger Name des 3. Verfassers: Klaus-Dieter Sommer

Straube, Guido; Fischer Calderón, Sebastian J.; Ortlepp, Ingo; Manske, Eberhard
Fundamentals of dynamic sensor positioning with nanoscale accuracy by an inverse kinematic concept. - In: SMSI 2020, (2020), S. 307-308

A recent challenge in measurement science is the growing demand for machines allowing nanoscale positioning and measuring in large volumes. The moving stage principle typically used for these applications needs to be altered, considering the mass of the moving stage growing with the measuring volume. This paper proposes an inverted kinematic concept and discusses two approaches to the reconstruction of mirror profiles to compensate for deviations in the mirror topographies.



Omidian, Maryam; Néel, Nicolas; Manske, Eberhard; Pezoldt, Jörg; Lei, Yong; Kröger, Jörg
Structural and local electronic properties of clean and Li-intercalated graphene on SiC(0001). - In: DPG-Frühjahrstagung (DPG Spring Meeting) of the Condensed Matter Section (SKM) together with the DPG Division Environmental Physics and the Working Groups Accelerator Physics; Equal Opportunities; Energy; Industry and Business; Physics, Modern IT and Artificial Intelligence, Young DPG, (2020), O 80.3