02/2011: DE 10 2011 102 176.4, Seifert, B.-U., Schramm, S., Haueisen, J.: Vorrichtung und Verfahren zur simultanen Erfassung von Aberrationen und Streulichtkenngrößen eines optischen Systems
Listed below you will find a selection of important publications. For a complete overview please use the University Bibliography of the Technischen Universität Ilmenau.
Solf, B., Schramm, S., Blum, M.-C., Klee, S.: The Influence of the Stimulus Design on the Harmonic Components of the Steady-State Visual Evoked Potential. Frontiers in Human Neuroscience Bd. 14, Nr. 343. 2020
Solf, B., Schramm, S.,Link, D., Klee, S.: Objective measurement of forward-scattered light in the human eye: An electrophysiological approach. PLOS ONE Bd. 14, Nr. e0214850. 2019
Schramm, S., Schikowski, P., Lerm, E., Kaeding, A., Haueisen, J., Baumgarten, D.: Shack–Hartmann-based objective straylight assessment of the human eye in an increased scattering angle range. Journal of Biomedical Optics Bd. 21, Nr. 7, S. 076003 Juli 2016
Schramm, S., Seifert, B.-U., Schikowski, P., Prehl, J., Kunert, K. S., Blum, M.-C., Kaeding A., Haueisen, J.: A modified Hartmann–Shack aberrometer for measuring stray light in the anterior segment of the human eye. Graefes Arch. Clin. Exp. Ophthalmol., Bd. 251, Nr. 8, S. 1967–1977, Juni 2013
Peter, M., Kammel, R., Ackermann, R., Schramm, S., Seifert, B.-U., Frey, K., Blum, M.-C., Nolte, S., Kunert, K. S.: Analysis of optical side-effects of fs-laser therapy in human presbyopic lens simulated with modified contact lenses. Graefes Arch. Clin. Exp. Ophthalmol., Februar 2012
Schramm, S., Dietzel, A., Blum, M.-C., Link, D., Klee, S.: Light‐Field imaging of the human optic nerve head at different wavelengths—a case study. Januar 2021, Acta Ophthalmologica 99(S265)
Schramm, S., Solf, B., Klee, S.: Scatter measurement in the human eye based on a Shack‐Hartmann wavefront aberrometer with extended field of view. Januar 2021, Acta Ophthalmologica 99(S265)
Dietzel, A., Schramm, S., Link, D., Klee, S.: Light‐field imaging for glaucoma diagnosis—reproducibility on one patient. Januar 2021, Acta Ophthalmologica 99(S265)
Schramm, S., Dietzel, A., Link, L., Klee, S.: Light-field imaging of the human optic nerve head for glaucoma diagnosis. WOC2020 virtual, Juni 2020
Dietzel, A., Schramm, S., Link, L., Klee, S.: Light-Field imaging for glaucoma diagnosis – measurements on a phantom. WOC2020 virtual, Juni 2020
Solf, B., Schramm, S., Klee, S.: The effect of stray light on the electrophysiological measurement of the contrast threshold. BMT DGBMT Annual Conference, September 2019
Solf, B., Schramm, S., Link, D., Klee, S.: An electrophysiological approach for objective measurement of ocular stray light – a proof of principle. World Congress on Medical Physics & Biomedical Engineering, Juni 2018
Schramm, S., Schikowski, P., Lerm, E., Kaeding, A., Klemm, M., Haueisen, J., Baumgarten, D.: Objective straylight assessment of the human eye with a novel device. Photonics West – San Francisco2016
Walther, M., John, K., Schramm, S., Schikowski, P., Kaeding, A., Baumgarten, D.: Novel Shack-Hartmann based surface characterisation with extended spatial range and resolution. SPITSE – St. Petersburg, 2016
Schramm, S., Lerm, E., Schikowski, P., Kunert, K., Baumgarten, D.: Plausibility of a new method for measurement of forward scattered light in the human eye with a Shack-Hartman Wavefront Aberrometer. ARVO – Orlando 2014
Lerm, E., Schramm, S., Schikowski, P., Kaeding, A., Baumgarten, D.: A Measurement System for forward stray light analysis of the human eye. SPITSE – Ilmenau, 2014
Schramm, S., Lerm, E., Schikowski, P., Kaeding, A., Baumgarten, D.: Streulichtmessung am Auge mit einem neuartigen Wellenfrontaberrometer mit Hartmann-Shack-Sensor. Arbeitskreist Ophthalmologische Optik – Ilmenau 2014
Schramm, S., Seifert, B.-U., Haueisen, J., Schikowski, P., Prehl, J., Kaeding, A., Kunert, K. S.: Comparative Investigation in Stray Light Measurement in the Human Eye. in Proceedings BMT 2012, Jena, 2012, S. 1862–278X
Schramm, S., Schikowski, P., Reder, M., Kunert, K., Seifert, B.-U.: Plausibility of Stray Light Measurement with a modified Wavefront Analyzer. ARVO Meet. Abstr., Bd. 52, Nr. 6, S. 6217, Apr. 2011
Schramm, S., Seifert, B.-U.: Streulichtmessung mit Hartmann-Shack-Sensor am Auge. in DGaO-Proceedings 2011, 2011
Seifert, B.-U., Schikowski, P., Kunert, K. S., Reder, M., Schramm, S.: Enhanced Feature Segmentation and Data Extraction in Pentacam Scheimpflug Images. ARVO Meet. Abstr., Bd. 52, Nr. 6, S. 5707, Apr. 2011
Kunert, K. S., Nennstiel, M., Blum, M.-C., Schramm, S., Seifert, B.-U., Schikowski, P., Prehl, J., Reder, M.: Presbyopia is the First Stage of Nuclear Cataract-Analysis of Forward and Backward Scattered Straylight in the Presbyopic Human Lens. ARVO Meet. Abstr., Bd. 52, Nr. 6, S. 826, Apr. 2011
Reder, M., Blum, M.-C., Schramm, S., Seifert, B.-U., Ackermann, R., Kammel, R., Nolte, S., Kunert, K. S.: Analysis of Optical Side Effects of fs-Laser Therapy in the Human Presbyopic Lens Simulated With Modified Contact Lenses. ARVO Meet. Abstr., Bd. 52, Nr. 6, S. 6215, Apr. 2011
Schramm, S., Seifert, B.-U., Link, D.: Influence of the Shell Structure of the Human Lens on Accommodation Using Ray Tracing. ARVO Meet. Abstr., Bd. 51, Nr. 5, S. 790, Apr. 2010.
Seifert, B.-U.,Schramm, S., Bessler, P., Schikowski, P., Kunert, K. S.: Clinical Validation of a Modified Wavefront Analyzer - Preliminary Results. ARVO Meet. Abstr., Bd. 51, Nr. 5, S. 3948, Apr. 2010